Case Range |
Minimum |
Maximum |
| A |
5-1/2" |
22" |
| B |
2-7/8" |
8" |
| L |
7" |
22-3/4" |
| W |
5-3/4" |
16" |
| H |
3" |
15" |
| E |
12" |
38" |
|
 |
K.D.
length: 12" to 38"
K.D. width: 8" to 29-1/4" |
- Case
range: RSC and HSC cases
- Electrical: Primary 230 or 460v,
60hz, 3ph, NEMA 12
- Air: 0.54 scfm per cycle at 80 psi
- Speed: Up to 55 cases/minute
|
| |
|
| |
|
|
Pro Forma 450 Hot Melt Case Erector / Bottom Sealer - Standard Features |
High
Performance Features:
- Heavy steel box frame construction- welded and bolted for strength
- All-mechanical main drive (3 hp motor)
- Servo-controlled sealing ram
- High capacity vacuum system
- Direct drive walking beam case transfer
Features for Reliable Operation:
- A-B-C's Intelligent Control electronics
provide total control
of operation
- Low level case
magazine holds 3 stacks of cases (approx. 300 kd's)
eliminating frequent refills
- Automatic case feed from top
of stack to smoothly feed warped or band-marked cases
- Dual top
and bottom vacuum grippers that over-open cases ensuring proper
opening of cases with poor manufacturer's
joints
- Reliable walking beam case transfer
Reduced Maintenance Features:
- Non-contact sensors monitor machine
operation
- Sealed bearings throughout
- Gull-wing style high visibility machine
doors allow easy machine access
- Touchscreen control for machine
jog, diagnostics, troubleshooting, changeover settings
- Back-up
eye for surge control
- Elevated beacon fault light
A-B-C's Intelligent Control gives you more
Included in the
base price of the machine, this package features:
Variable
speed capability:
- 20 - 55 cases per minute (dependent on case sizes)
- Speed ramps
up and down to suit line speed- all settings (including adhesive
application) are automatically adjusted as speed changes
- Soft
Stop - quits operation without dumping air
- Cycle stop - cycles
out all cases before stop
- Main drive jog function
- Manual operation of all functions including
glue test
Standard fault
detection features:
- Downstream case backup
- Case magazine is empty or low
- No / low air pressure
- Guard door opened
- Case did not open properly
- Emergency stop activated
- Motor overload
- Photo eye is dirty or misaligned
- Encoder or coupling malfunction
- Individual sensor malfunction
- Minimum speed fault
Optional features:
- Magazine extensions for additional knockdown blank capacity
- Repeatable position
indicators on adjustment shafts
- Grouped lubrication fittings
|