Model 330 Hot Melt Case Erector / Bottom Sealer - Specifications |
Case Range |
Minimum |
Maximum |
| A |
5-1/2" |
22" |
| B |
2-7/8" |
8" |
| L |
7" |
22-3/4" |
| W |
5-3/4" |
16" |
| H |
3" |
15" |
| E |
12" |
38" |
|
 |
K.D. length: 12" to 38"
K.D. width: 8" to 29-1/4" |
- Case range: RSC and HSC cases
- Electrical: Primary 230 or 460v, 60hz, 3ph, NEMA 12
- Air: 0.54 scfm per cycle at 80 psi
- Speed: Up to 35 cases/minute
|
| |
|
| |
|
|
Model 330 Hot Melt Case Erector / Bottom Sealer - Standard Features |
High Performance Features:
- Heavy steel box frame construction- welded and bolted for strength
- All-mechanical main drive
- High capacity vacuum system
- Direct drive walking beam case transfer
Features for Reliable Operation:
- A-B-Cs Intelligent Control electronics provide total control
of operation
- Low level case magazine holds 3 stacks of cases (approx. 300
kds) eliminating frequent refills
- Automatic case feed from top of stack by dual floating grippers
to smoothly feed warped or band-marked cases
- Dual top and bottom vacuum grippers that over-open cases ensuring
proper opening of cases with poor manufacturers joints
- Reliable walking beam case transfer
Reduced Maintenance Features:
- Non-contact sensors monitor machine operation
- Sealed bearings throughout
- Gull-wing style high visibility machine doors allow easy machine
access
- Touchscreen control for machine jog, diagnostics, troubleshooting,
changeover settings
- Back-up eye for surge control
- Elevated beacon fault light
A-B-C's Intelligent Control gives you more
Included in the
base price of the machine, this package features:
Variable
speed capability:
- 10 - 35 cases per minute (dependent on case sizes)
- Speed ramps up and down to suit line speed- all settings (including
adhesive application) are automatically adjusted as speed changes
- Soft Stop - quits operation without dumping air
- Cycle stop - cycles out all cases before stop
- Main drive jog function
- Manual operation of all functions including glue test
Standard fault
detection features:
- Downstream case backup
- Case magazine is empty or low
- No / low air pressure
- Guard door opened
- Case did not open properly
- Emergency stop activated
- Motor overload
- Photo eye is dirty or misaligned
- Encoder or coupling malfunction
- Individual sensor malfunction
- Minimum speed fault
Optional features:
- Magazine extensions for additional capacity
- CSSC case capability
- Repeatable position indicators on adjustment shafts
- Grouped lubrication fittings
|